I have faced a problem when integrating Lync with Exchange 2010 UM , where calls could not be established to UM for external users, whenever i call the susbscriber access from the Internet i get the following error: "call failed due to network issues. try logging out of lync logging back in, or try again later" After revewing the logs, i found the following entry in the event viewer on the Lync front-end server : Event ID: 1400 Source: MSExchange Unified Messaging The following UM IP gateways did not respond as expected to a SIP OPTIONS request. Transport = TLS, Address = lyncfe.domain.com, Port = 5061, Response Code = 0, Message = This operation has timed out. Solution: Issue a certificate dedicated to UM, where the subject name is the FQDN of the UM server.
I am blogging about Microsoft Cloud and Security Solutions